UnitekFiber supplies High Quality ABS cassette PLC Splitters assembly. The chip part is packed by a black ABS cassette and uses a 2.0mm or 3.0mm loose tube fiber cables for optical delivery.The SC, LC, ST and FC connectors are connected at the end of the fiber cable.
lLow Insertion loss
lLow PDL
lCompact Design
lGood channel-to-channel uniformity
lWide Operating Wavelength:
lFrom 1260nm to 1650nm
lWide Operating Temperature
lHigh Reliability and Stability
lFTTX Systems
lPON Networks
lCATV Links
lOptical Signal Distribution
lTelcordia GR-1209-CORE
lTelcordia GR-1221-CORE
Table 1 – 1×N PLC Splitter
Parameters | 1×2 | 1×4 | 1×6 | 1×8 | 1×12 | 1×16 | 1×32 | 1×64 | |
Operating Wavelength (nm) | 1260~1650 | ||||||||
Fiber Type | G657A or customer specified | ||||||||
Insertion Loss (dB)(Min/Max) | 3.8/4.0 | 7.2/7.4 | 9.5/9.8 | 10.5/10.7 | 12.1/12.6 | 13.5/13.7 | 16.5/16.9 | 20.5/21.0 | |
Loss Uniformity (dB) | 0.6 | 0.6 | 1.0 | 0.8 | 1.1 | 1.2 | 1.5 | 2.5 | |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | |
Polarization Dependent Loss(dB) | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.4 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | |
Operating Temperature(℃) | -40~+85 | ||||||||
Storage Temperature(℃)) | -40~+85 | ||||||||
Operating Humidity | 5% ~ 85% RH | ||||||||
Storage Humidity | 5% ~ 85% RH | ||||||||
Device Dimension (mm) (L×W×H) | 40×4×4 | 40×4×4 | 40×4×4 | 40×4×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×12×6 | |
Module Dimension (mm) (L×W×H) | 100×80×10 | 100×80×10 | 100×80×10 | 100×80×10 | 120×80×18 | 120×80×18 | 120×80×18 | 140×115×18 | |
Mini-Module Dimension (mm) (L×W×H) | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×12×4 | 80×20×6 | 100×40×6 |
Table 2 – 2×N PLC Splitter
Parameters | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | |
Operating Wavelength (nm) | 1260~1650 | ||||||
Fiber Type | G657A or customer specified | ||||||
Insertion Loss (dB)(Min/Max) | 3.9/4.2 | 7.5/7.8 | 11.2/11.5 | 14.2/14.5 | 17.2/17.7 | 21.0/21.5 | |
Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 1.8 | 2.0 | 2.5 | |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
Polarization Dependent Loss(dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
Operating Temperature(℃)) | -40~+85 | ||||||
Storage Temperature(℃)) | -40~+85 | ||||||
Operating Humidity | 5% ~ 85% RH | ||||||
Storage Humidity | 5% ~ 85% RH | ||||||
Device Dimension (mm) (L×W×H) | 50×4×4 | 50×4×4 | 50×4×4 | 60×7×4 | 60×7×4 | N/A | |
Module Dimension (mm) (L×W×H) | 100×80×10 | 100×80×10 | 100×80×10 | 120×80×18 | 120×80×18 | 140×115×18 | |
Mini-Module Dimension (mm) (L×W×H) | 60×7×4 | 60×7×4 | 60×7×4 | 80×12×4 | 80×20×6 | N/A |