Fiber optical splitter is a passive device that transforms signals by one or two input optical signal to several output optical signals. According to different basic principle, it can divide into Fused type and PLC type. PLC can meet the needs of different wavelengths with spectral uniformity and compact structure. Fused type can be customized of any coupling ratio.
lLow Insertion loss
lLow PDL
lCompact Design
lGood channel-to-channel uniformity
lWide Operating Wavelength:
lFrom 1260nm to 1650nm
lWide Operating Temperature
lHigh Reliability and Stability
lFTTX Systems
lPON Networks
lCATV Links
lOptical Signal Distribution
lTelcordia GR-1209-CORE
lTelcordia GR-1221-CORE
Table 1 – 1×N PLC Splitter
Parameters | 1×2 | 1×4 | 1×6 | 1×8 | 1×12 | 1×16 | 1×32 | 1×64 | |
Operating Wavelength (nm) | 1260~1650 | ||||||||
Fiber Type | G657A or customer specified | ||||||||
Insertion Loss (dB)(Min/Max) | 3.8/4.0 | 7.2/7.4 | 9.5/9.8 | 10.5/10.7 | 12.1/12.6 | 13.5/13.7 | 16.5/16.9 | 20.5/21.0 | |
Loss Uniformity (dB) | 0.6 | 0.6 | 1.0 | 0.8 | 1.1 | 1.2 | 1.5 | 2.5 | |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | |
Polarization Dependent Loss(dB) | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.4 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | 55 | 55 | |
Operating Temperature(℃) | -40~+85 | ||||||||
Storage Temperature(℃)) | -40~+85 | ||||||||
Operating Humidity | 5% ~ 85% RH | ||||||||
Storage Humidity | 5% ~ 85% RH | ||||||||
Device Dimension (mm) (L×W×H) | 40×4×4 | 40×4×4 | 40×4×4 | 40×4×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×12×6 | |
Module Dimension (mm) (L×W×H) | 100×80×10 | 100×80×10 | 100×80×10 | 100×80×10 | 120×80×18 | 120×80×18 | 120×80×18 | 140×115×18 | |
Mini-Module Dimension (mm) (L×W×H) | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×7×4 | 60×12×4 | 80×20×6 | 100×40×6 |
Table 2 – 2×N PLC Splitter
Parameters | 2×2 | 2×4 | 2×8 | 2×16 | 2×32 | 2×64 | |
Operating Wavelength (nm) | 1260~1650 | ||||||
Fiber Type | G657A or customer specified | ||||||
Insertion Loss (dB)(Min/Max) | 3.9/4.2 | 7.5/7.8 | 11.2/11.5 | 14.2/14.5 | 17.2/17.7 | 21.0/21.5 | |
Loss Uniformity (dB) | 0.8 | 1.5 | 1.5 | 1.8 | 2.0 | 2.5 | |
Return Loss (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
Polarization Dependent Loss(dB) | 0.2 | 0.2 | 0.4 | 0.4 | 0.4 | 0.4 | |
Directivity (dB) | 55 | 55 | 55 | 55 | 55 | 55 | |
Operating Temperature(℃)) | -40~+85 | ||||||
Storage Temperature(℃)) | -40~+85 | ||||||
Operating Humidity | 5% ~ 85% RH | ||||||
Storage Humidity | 5% ~ 85% RH | ||||||
Device Dimension (mm) (L×W×H) | 50×4×4 | 50×4×4 | 50×4×4 | 60×7×4 | 60×7×4 | N/A | |
Module Dimension (mm) (L×W×H) | 100×80×10 | 100×80×10 | 100×80×10 | 120×80×18 | 120×80×18 | 140×115×18 | |
Mini-Module Dimension (mm) (L×W×H) | 60×7×4 | 60×7×4 | 60×7×4 | 80×12×4 | 80×20×6 | N/A |