Description: 

Indoor/outdoor fiber optic cables can not only meet the flame retardant requirements of indoor use, but also meet the needs of outdoor use. This fiber cable structure is putting 2-24 of 250um bare fibers in a PBT loose tube. And the Kevlar yarn is requested as reinforcement to enhance tensile resistant.The standard sheath is made of low-smoke, halogen-free, flame-retardant materials.


                

  • Uni-tube Indoor|Outdoor Fiber Optic Drop Cable 12 24 fibers G657A2 OS2 Single Mode|Multimode Rated LSZH Black
  • Uni-tube Indoor|Outdoor Fiber Optic Drop Cable 12 24 fibers G657A2 OS2 Single Mode|Multimode Rated LSZH Black
  • Uni-tube Indoor|Outdoor Fiber Optic Drop Cable 12 24 fibers G657A2 OS2 Single Mode|Multimode Rated LSZH Black
  • Uni-tube Indoor|Outdoor Fiber Optic Drop Cable 12 24 fibers G657A2 OS2 Single Mode|Multimode Rated LSZH Black


Features:

  • Fiber type: ITU-T- G652D, G657A fiber, G657B fiber

  • It has good mechanical and environmental performance

  • Flame (or not flame retardant) performance to meet the requirements of the standard

  • Mechanical and physical properties of the sheath to meet the relevant standards Soft, flexible and convenient

  • UV stablized and Flame-retardent LSZH outer jacket


Application:

  • This fiber cable is applied in Duct, Aerial FTTx, Access installations.

  • Used as access building cable in premises distribution system, especially used in indoor or outdoor aerial access cabling.

  • For optical communication equipment room, optical distribution frame optical

  • Connection

  • For pigtails and jumpers


Product Parameter


No. of cable

24

Fiber Model

G.652D

Material

PBT


Diameter(±0.03)mm

0.35


Thickness(±0.06)mm

3.0


Material

LSZH


Thickness(±0.1)mm

1.3


Cable Diameter(±0.2)mm

6.4

Cable Weight(±5)kg/km

49

Min. bending radius

Without Tension

15.0×Cable-φ

Under Maximum Tension

20.0×Cable-φ

Temperature range
(℃)

Installation

-5~+50

Transport&Storage

-30~+70

Operation

-20~+70



Transmission Characteristics:


Characteristics

Conditions

Specified Values

Units

Geometrical characteristics

Cladding diameter


125.0±0.7

µm

Cladding non-circularity


≤0.7

%

Coating diameter


242±5

µm

Coating/cladding concentricity error

<12

µm

Core/cladding concentricity error

≤0.5

µm

Curl

≥4

m

Optical characteristics

Attenuation

1310nm

≤0.4

dB/km

1383nm

≤0.4

dB/km

1490nm

≤0.3

dB/km

1550nm

≤0.3

dB/km

1625nm

≤0.3

dB/km

Attenuation vs. Wavelength
max. A difference

1285~1330nm

≤0.03

MHz*km

1525~1575nm

≤0.02

MHz*km

Dispersion coefficient

1550nm

≤18

ps/(nm*km)

1625nm

≤22

ps/(nm*km)

Zero dispersion wavelength


1304~1324

nm

Zero dispersion slope


≤0.092

ps/(nm2*km)

Polarization mode dispersion




PMD maximum individual fibre


≤0.1

ps/km1/2

PMD design link value


≤0.04

ps/km1/2

Cable cut off wavelength


≤1260

nm

Mode field diameter

1310nm

8.8~9.6

µm

1550nm

9.9~10.9

µm

Group index of refraction

1310nm

1.4691


1550nm

1.4696


Environmental characteristics

1310nm、1550nm&1625nm


Temperature cycling

-60℃ to +85℃

≤0.05

dB/km

Temperature-humidity cycling

-10℃ to +85℃

4% to 98% RH

≤0.05

dB/km

Water immersion

23℃, 30 days

≤0.05

dB/km

Dry heat

85℃, 30 days

≤0.05

dB/km

Damp heat

85℃, 85%RH, 30 days

≤0.05

dB/km

Mechanical specification

Proof test

≥100

kpsi

Macro bending induced loss




1Turns @10mm Radius

1550nm

≤0.5

dB

1Turns @10mm Radius

1625nm

≤1.5

dB

10Turns @15mm Radius

1550nm

≤0.05

dB

10Turns @15mm Radius

1625nm

≤0.30

dB

100Turns @25mm Radius

1310&1550&1625 nm

≤0.01

dB

Dynamic stress corrosion susceptibility parameter

20



Fibre Colours



No.

1

2

3

4

5

6

7

8

9

10

11

12

Color

Red

Blue

Green

Yellow

Violet

White

Orange

Gray

Brown

Light Green

aqua

pink














No.

13

14

15

16

17

18

19

20

21

22

23

24

Color

Red

Blue

Green

Yellow

Violet

White

Orange

Gray

Brown

Light Green

aqua

pink



Packaging & Shipping

All-dielectric Micro-tube Building Vertical Wiring Fiber Cable (GJPFH) packing and shipping
Leave us Message EMAIL_US
Products
News
  • How to terminate fiber optic cable
    In order to improve the work efficiency of data center engineers with less time and lower cost, and ensure the performance and stability of the data center, the pre-terminated optical fiber cabling so...
  • How to check the optical signal strength of the SFP optical module?
    When the SFP optical module and the switch are connected, the optical signal strength is a key parameter to ensure the normal operation of the entire connection. What is a fiber optic transceiver? As ...
  • How do fiber optic cables work
    Optical fiber cable is a communication cable composed of two or more glass, plastic optical fiber cores and cladding layers. how does fiber optic cable work?Generally, lasers are used for internal sig...